1. Support EtherCAT, Profinet protocol

Specifications

ModelkW | HP | Power capacity (kVA) | Rated input current(A) | Rated output current(A) | Integrated with brake function
Input : Three-phase 380~480V & Output Three-phase 0~Input
VC-4T045-E45 | 60 | 69 | 92 | 91 | Optional
VC-4T055-E55 | 70 | 85 | 113 | 112 | Optional
VC-4T075-E75 | 100 | 114 | 157 | 150 | Optional
VC-4T093-E93 | 125 | 134 | 180 | 170 | Optional
VC-4T0110-E110 | 150 | 160 | 214 | 210 | Optional
VC-4T0132-E132 | 180 | 192 | 256 | 253 | Optional
VC-4T0160-E160 | 220 | 231 | 307 | 304 | Optional
ItemSpecification
Controlled CharacteristicControl mode | V/F | SVC
Starting torque1Hz/100% Rated torque | 0.5Hz/150% Rated torque
Range of speed regulation1:50 | 0.111111111
Rotating speed≤1% Rated synchronous speed | ≤0.5% Rated synchronous speed
Carrier srequency0.6kHz~16kHz
Overload capacity150% Rated current 60s;180% Rated current 2s
Torque boostAutomatic torque increase; Manual torque increase 0.1~30.0%
I/OThe range of input voltage | Single-phase 200V-240V;Three-phase 380V-480V Allowable fluctuation range:-15%~10%
The range of input frequency50/60Hz Allowable fluctuation range:±5%
The range of output voltage0~Input,Fluctuation range:<5%
The range of output frequencySVC:0-500Hz V/F:0-1000Hz Fluctuation range:±5% of Maximum frequency
Run ControlRun command channel | 3 kinds of channels: Operation panel setting, Control terminal setting, Serial communication port given, Can change by different ways
Frequency sourceDigital setting, panel pulse potentiometer setting, linear voltage setting, curve voltage setting, analog current setting, serial communication setting, etc. Can be switched in a variety of ways
Auxiliary frequency sourceMultiple auxiliary frequency sources. Frequency synthesis and frequency fine-tuning can be performed
Digital input terminalThere are four DI1-DI4, of which DI4 supports high-speed pulse input, up to 20kHz input, and supports NPN PNP switching
Analog input terminalTwo AI1-AI2 (You can change the terminal function to DI input by setting parameters) The AI2 can switch the current/voltage input through the jumper cap
Basic FunctionDC braking function | DC braking frequency:0.00 Hz ~ 60.00 Hz;Braking time:0.0 s ~ 60.0s
Braking action current value:0.0% ~ 150.0%
V/F curveLinear, multi-point type, square type, 1.1-1.9 power curve, V/F completely separated type
Acceleration and deceleration curvesLinear or S-curve acceleration and deceleration mode, acceleration and deceleration time range:0~6500s
Multi-speed operationUp to 16 segment speeds are achieved through the control terminal
External keyboardStandard, can upload and down-transfer inverter function code information, to achieve fast parameter replication
Built-in PIDIt is convenient to realize the closed-loop control system of process control
Automatic voltage adjustment AVRStandard, automatic current and voltage limit during operation to prevent frequent overvoltage trip
Over voltage over loss rate controlAutomatic current and voltage limit during operation to prevent frequent overvoltage trip
Fast current limiting functionThe standard configuration minimizes overcurrent faults and protects the normal operation of the equipment
Torque qualification and controlAutomatic torque limit during operation to prevent frequent overcurrent tripping
Power on the safety self-test of peripheral devicesIt can realize the safety detection of peripheral devices such as grounding and short circuit
Timing control functionTiming control function: set time range 0h ~ 65000h
Defensive functionPower-on motor short circuit detection, input and output phase loss protection, over current protection, over voltage protection, under voltage protection, overheat protection, overload  protection
Display and Keyboard OperationLED display | 5 digit LED display
Parameter locking functionSet parameter read-only control to prevent misoperation
Service EnvironmentPlace of use | Indoor, free from direct sunlight, no dust, corrosive gas, flammable gas, oil mist, water vapor, dripping or salt
AltitudeLess than 1000m; When the sea level is higher than 1000m, the sea level must be reduced by 1% for every 100m rise. The maximum sea level is 2000m
Environment temperature-20℃~45℃,Derating is required when the temperature exceeds 45℃. For every 1℃ increase in the ambient temperature, the derating is about 1%. The maximum ambient temperature is 50℃
Humidity≤95%RH,Avoid condensation
VibrationVibration acceleration less than 0.6g
Storage temperature-25℃~60℃
ModelExternal Dimension(mm) | Installation Dimension (mm) | Hole Size (mm)
HW | D | D1 | H1 | W1 | d
VC-4T045-E500 | 230 | 323 | 330 | 481.5 | 160 | 8
VC-4T055-E
VC-4T075-E595 | 260 | 360 | 367 | 569.5 | 190 | 8
VC-4T093-E
VC-4T110-E
VC-4T132-E660 | 330 | 422 | 429 | 640 | 200 | 10
VC-4T160-E