Description

Up to 16 extension modules

Specifications

ItemLX6V-EMB-ECAT | LX6V-EM C -ECAT
Rated I nput V oltageDV 24V±10%@100mA (excluding expansion module)
Communication I nterfaceRJ45×2, EtherCAT communication protocol with performance100Mbps: IN interface is EtherCAT input port; OUT interface is an EtherCAT output port, which is used for connecting the subsequent EtherCAT slave;
Transmission D istanceLength of communication line between two nodes≤100m
Transmission M ediumCategory 5E (cat 5e) cable or above
Single AP P rocess D ataMaximum input and output 1024 bytes
Synchronous P eriodMinimum 125us
Allowable I nstantaneous P ower O utage T ime10ms
Impulse C urrent≤ 45A (with maximum module load)
Power P rotectionAnti-reverse connection protection, overcurrent protection and surge absorption
Maximum N umber of E xpansion M odules16 | 32
Firmware U pgradeSupport
Serial N umberInterface | Function D efinition
1Signal I ndicator | PWR | Power indicator | Off | No power supply
OnWhen the power supply is on
RUNRunning indicator | Off | ECT module is in INIT status
Flashing (white)ECT module is in PreOp status
Single flash (white)ECT module is in Safe-Op status
Normally on (white)ECT module is in Operational status
ERRCommunication fault indicator | Off | EtherCAT communication is in normal status
Flashing (Red)EtherCAT communication receives status transition instructions that cannot be executed
Single flash (red)Network disconnection, ECT module synchronization error
Normally on (Red)Watchdog error occurred in EtherCAT communication
2USB Communication Interface (Type-C) | Used for single board software upgrade
3EtherCAT I nterface | IN: EtherCAT input port
OUT: EtherCAT output interface
424V power I nput I nterface | Module power input terminal
5Expansion M odule I nterface | Connect LX6V Series expansion module
6Mounting H ole | 2 places, φ4.5
7DIN R ail F astener